Today's bandwidth expectations mean that Category 5 is strategically
dead. The Category 5 Enhanced (5e) standards, which should have been
ratified in August and may be finalized at November's committee meeting,
specify new measurements that provide more margins for 100BaseTX and
ATM-155 traffic. Critically, Category 5e standards make reliable Gigabit
Ethernet connections possible. But many structured cabling suppliers
argue that Category 5e is only an interim solution on the road to
Category 6, which will support at least 200 MHz; in the interests of
sufficient operating margin, the IEEE is requesting a 250-MHz Category 6
specification. Despite the fact that the Category 6 standards are only
at draft stage, manufacturers are offering a host of products and
claiming that these products comply with the draft proposals.
What is a category 6 cable? Out of the three cable categories
(Cat-5, Cat-5e & Cat-6), Category 6 is the most advanced and
provides the best performance. Just like Cat 5 and Cat 5e, Category 6
cable is typically made up of four twisted pairs of copper wire, but its
capabilities far exceed those of other cable types because of one
particular structural difference: a longitudinal separator. This
separator isolates each of the four pairs of twisted wire from the
others, which reduces crosstalk, allows for faster data transfer, and
gives Category 6 cable twice the bandwidth of Cat 5! Cat 6 cable is
ideal for supporting 10 Gigabit Ethernet, and is able to operate at up
to 250 MHz. Since technology and standards are constantly evolving, Cat 6
is the wisest choice of cable when taking any possible future updates
to your network into consideration. Not only is Category 6 cable
future-safe, it is also backward-compatible with any previously-existing
Cat 5 and Cat 5e cabling found in older installations.
Category 6, (ANSI/TIA/EIA-568-B.2-1) is a cable standard for Gigabit
Ethernet and other network protocols that is backward compatible with
the Category 5, category 5e and Category 3 cable standards. Cat-6
features more stringent specifications for crosstalk and system noise.
The cable standard is suitable for 10BASE-T / 100BASE-TX and 1000BASE-T
(Gigabit Ethernet) and is expected to suit the 10000BASE-T (10Gigabit
Ethernet) standards. It provides performance of up to 250 MHz.
The cable contains four twisted copper wire pairs, just like earlier
copper cable standards. Although Cat-6 is sometimes made with 23 gauge
wire, this is not a requirement; the ANSI/TIA-568-B.2-1 specification
states the cable may be made with 22 to 24 AWG gauge wire, so long as
the cable meets the specified testing standards. When used as a patch
cable, Cat-6 is normally terminated in 8P8C often incorrectly referred
to as "RJ-45" electrical connectors. Some Cat-6 cables are too large and
may be difficult to attach to 8P8C connectors without a special modular
piece and are technically not standard compliant. If components of the
various cable standards are intermixed, the performance of the signal
path will be limited to that of the lowest category. As with all cables
defined by TIA/EIA-568-B, the maximum allowed length of a Cat-6
horizontal cable is 90 meters (295 feet). A complete channel (horizontal
cable plus cords on either end) is allowed to be up to 100 meters in
length, depending upon the ratio of cord length: horizontal cable
length.
The cable is terminated in either the T568A scheme or the T568B
scheme. It doesn't make any difference which is used, as they are both
straight through (pin 1 to 1, pin 2 to 2, etc). Mixed cable types should
not be connected in serial, as the impedance per pair differs and would
cause signal degradation. To connect two Ethernet units of the same
type (PC to PC, or hub to hub, for example) a cross over cable should be
used, though some modern hardware can use either type of cable
automatically.
Return loss measures the ratio of reflected-to-transmitted signal
strength and is the single most difficult test to repeat with consistent
results; at Category 6 levels, the difference between a pass and a fail
can be the amount of bend in a test cord. Return loss is also causing
headaches for connector manufacturers, because the RJ-45 system isn't up
to the job. The final stumbling block with Category 5e ratification
concerns the RJ-45 hardware; Category 6 is committed to RJ-45 for
backward compatibility, but the ISO's proposed Category 7 system will
have a new and as-yet-unspecified connector to accompany its revised
cabling. Today, the return loss problem explains why manufacturers of
Category 6 hardware, which is supposed to be interoperable, claim
Category 6 performance only if you use the manufacturers' matched parts
throughout a channel link.
The Telecommunications Industry Association (TIA) is working to
complete a new specification that will define enhanced performance
standards for unshielded twisted pair cable systems. Draft specification
ANSI/TIA/EIA-568-B.2-10 specifies cable systems, called "Augmented
Category 6" or more frequently as "Category 6a", that operates at
frequencies up to 500 MHz and will provide up to 10 Gbit/s bandwidth.
The new specification has limits on alien crosstalk in cabling systems.
Augmented Category 6 specifies cable operating at minimum frequency
of 500 MHz, for both shielded and unshielded. It can support future 10
Gb/s applications up to the maximum distance of 100 meters on a
4-connector channel.